• Home
  • Submit Paper
  • Check Paper Status
  • Download Certificate/Paper
  • FAQs
  • Contact Us
Email: ijraset@gmail.com
IJRASET Logo
Journal Statistics & Approval Details
Recent Published Paper
Our Author's Feedback
 •  ISRA Impact Factor 7.894       •  SJIF Impact Factor: 7.538       •  Hard Copy of Certificates to All Authors       •  DOI by Crossref for all Published Papers       •  Soft Copy of Certificates- Within 04 Hours       •  Authors helpline No: +91-8813907089(Whatsapp)       •  No Publication Fee for Paper Submission       •  Hard Copy of Certificates to all Authors       •  UGC Approved Journal: IJRASET- Click here to Check     
  • About Us
    • About Us
    • Aim & Scope
  • Editorial Board
  • Impact Factor
  • Call For Papers
    • Submit Paper Online
    • Current Issue
    • Special Issue
  • For Authors
    • Instructions for Authors
    • Submit Paper
    • Download Certificates
    • Check Paper Status
    • Paper Format
    • Copyright Form
    • Membership
    • Peer Review
  • Past Issue
    • Monthly Issue
    • Special Issue
  • Pay Fee
    • Indian Authors
    • International Authors
  • Topics
ISSN: 2321-9653
Estd : 2013
IJRASET - Logo
  • Home
  • About Us
    • About Us
    • Aim & Scope
  • Editorial Board
  • Impact Factor
  • Call For Papers
    • Submit Paper Online
    • Current Issue
    • Special Issue
  • For Authors
    • Instructions for Authors
    • Submit Paper
    • Download Certificates
    • Check Paper Status
    • Paper Format
    • Copyright Form
    • Membership
    • Peer Review
  • Past Issue
    • Monthly Issue
    • Special Issue
  • Pay Fee
    • Indian Authors
    • International Authors
  • Topics

Ijraset Journal For Research in Applied Science and Engineering Technology

  • Home / Ijraset
  • On This Page
  • Abstract
  • Introduction
  • Conclusion
  • References
  • Copyright

Analysis & Design of G+5 Residential Building Using STAAD-PRO

Authors: Akash Deep, Akshay Deep

DOI Link: https://doi.org/10.22214/ijraset.2023.51888

Certificate: View Certificate

Abstract

Structural planning and design is an art and science of designing with economy elegance and durable structure. The entire process of structural planning and designing is not only requires imagination and conceptual thinking but also sound knowledge of structural engineering besides knowledge of practical aspects such as relevant design codes and by-loss backed up by example experiences. The purpose of standards is to ensure and enhance the safety, keeping careful balance between economy and safety. In the present study G+5 building of 9.0mX15.2m.Area 136.8sqmeter at Badarpur New Delhi , is designed (Slabs, Beams, Columns and Footings) using STADD PRO software. In order to design them, it is important to first obtain the plan of the particular building that is, positioning of the particular rooms (Drawing room, bed room, kitchen toilet etc.) such that they serve their respective purpose and also suiting to the requirement and comfort of the inhabitants. Thereby depending on the suitability; plan layout of beams and the position of columns are fixed.

Introduction

I.  INTRODUCTION

A building frame consists of number of bays and storey. A multistorey, multi-paneled frame is a complicated statically intermediate structure. A design of R.C building of G+5storey frame work is taken  up. The building in plan (9.0mX15.2m) consists of columns built monolithicall forming a network. The size of building is 8.5X14.7m. The number of columns are 17. it is`1 residential complex. The design is made using software on structural analysis design

(staad-pro). The building subjected to both the vertical loads as  well as horizontal loads. The vertical load consists of dead load of structural components such as beams, columns, slabs etc and live loads. The horizontal load consists of the wind forces thus building is designed for dead load, live load and wind load as per IS 875. The building is designed as two dimensional vertical frame and analyzed for the maximum and minimum bending moments and shear forces by trial and error methods as per IS456-2000. The help is taken by software available in institute and the computations of  loads, moments and shear forces and obtained from this software.

Conclusion

From the work carried out in staad pro we can conclude that 1) Using STAAD.Pro the analysis of multi storey building has completed much quicker when compare with manual analysis (Kani\\\'s method) 2) It is observed that the reinforcement percentage in the sections is more in the case of software design when compared to manual calculations. 3) Designing using Software\\\'s like Staad reduces lot of time in design work. 4) Reinforcement Details of each and every member can be obtained using staad pro. 5) All the List of failed frame sections can be Obtained in the report given by Staad Pro so that we can change the property data for a better setion. 6) Shear variation and moment variation of particular section can be observed clearly on the building. 7) Accuracy is improved by using software. 8) Reinforcement details of each member can obtain directly after analysing the building.

References

[1] IS 456:2000 Code of practice for plain and reinforced concrete [2] SP 16(S&T): 1980 Design aids for reinforced concrete to IS 456:1978

Copyright

Copyright © 2023 Akash Deep, Akshay Deep. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Download Paper

Paper Id : IJRASET51888

Publish Date : 2023-05-09

ISSN : 2321-9653

Publisher Name : IJRASET

DOI Link : Click Here