Structures constructed using Mivan technology offer significant advantages over traditional construction method. The specific material used in Mivan formwork directly impacts both the durability and compressive strength of the resulting concrete. A detailed study is done to understand structural behaviour of the building with opening in Mivan building will be carried out. In the present study a G+11, G+13 and G+15 stories structure with the provision of various percentage of openings (20%, 35% and 50%) are taken into consideration.
The seismic behaviour of 3D structure for these cases is compared for different seismic zones (Zone 3, Zone 4 and Zone 5) keeping the soil condition as constant. Equivalent Static Method and Response Spectrum Method is used for dynamic analysis of the G+11 (20%, 35% and 50% openings with Zone 3, 4 and 5), G+13 (20%, 35% and 50% openings with zone 3,4 and 5) and G+15 (20%, 35% and 50% openings with zone 3, 4 and 5) story building using ETABS. Structural key parameters such as time period, maximum story displacement, base shear and story stiffness are compared with different building configurations in the form of tables and graphs.
Based on the comparison done on different structural parameters a possible suitable structural configuration is selected in order to satisfy all the conditions in optimistic way.
Introduction
The text focuses on the structural modelling and seismic analysis of Mivan construction buildings with different percentages of wall openings. Mivan technology is a modern construction method that uses specially designed aluminium formwork to construct reinforced concrete walls, slabs, beams, and columns. It provides faster construction, better dimensional accuracy, reduced material wastage, and uniform structural quality. However, it requires proper planning, skilled labour, and a higher initial investment in formwork.
The main objective of the study is to investigate the seismic behaviour of G+11, G+13, and G+15 buildings with different wall opening percentages of 20%, 35%, and 50% under seismic Zones III, IV, and V.
A total of 27 structural models were developed using ETABS 22.5.0. The models were analysed by applying dead loads, live loads, and earthquake loads according to IS 1893 (Part 1): 2016. Both Equivalent Static Analysis and Response Spectrum Analysis were performed to evaluate the structural behaviour.
The structural models were designed using the following parameters:
Floor height: 3 metres.
Concrete grade: M35.
Steel grade: HYSD500.
Slab thickness: 150 mm.
Wall thickness: 180 mm.
Soil type: Medium.
Damping ratio: 5%.
Response reduction factor: 4.
The study evaluates four important structural parameters:
1. Time Period: Measures the time required for a building to complete one cycle of vibration. The results show that the fundamental time period increases as the wall opening percentage increases from 20% to 50%, indicating a reduction in overall structural stiffness.
2. Maximum Storey Displacement: Represents the lateral movement of a building during earthquake loading. The analysis indicates that storey displacement increases with increasing wall opening percentage, suggesting greater lateral movement and reduced stiffness.
3. Base Shear: Represents the total horizontal earthquake force experienced by the building at its base. It is evaluated to understand the seismic force-resisting behaviour of different building configurations.
4. Storey Stiffness: Represents the resistance of individual floors against lateral deformation. It is examined to understand how different opening percentages influence the structural stiffness of the buildings.
The results indicate that increasing wall opening percentages generally increases the fundamental time period and maximum storey displacement. For example, the time period increases from 0.630 to 0.641 seconds for G+11, from 0.634 to 0.663 seconds for G+13, and from 0.783 to 0.823 seconds for G+15 buildings when openings increase from 20% to 50%.
Conclusion
1) The percentage increase in the fundamental time period when the opening percentage changes from 20% to 50% for G+11, G+13 and G+15 building configurations is approximately 1.75%, 4.57% and 5.11%.
2) The maximum story displacement for G+11 building configurations, subjected to earthquake loading in (EQX, EQY, RSX and RSY) X and Y- directions, for all opening percentages, the displacement in Zone 4 is approximately 50% higher than that in Zone 3 for the same percentage of openings, while the displacement in Zone 5 is approximately 50% higher than that in Zone 4.
3) The base shear increases with an increase in building height. The G+15 building shows approximately 8.16% higher average base shear in the X-direction and 8.14% higher average base shear in the Y-direction compared with the G+11 building. An increase in opening percentage from 20% to 35% results in an average reduction of approximately 4% in base shear, whereas an increase from 20% to 50% results in an average reduction of approximately 8%. Also, Among the three opening zones, Zone 5 exhibits higher base shear values, followed by Zone 4 and Zone 3, for corresponding opening configuration.
4) Story stiffness decreases with an increase in opening percentage. The 20% opening model demonstrates better stiffness characteristics compared with 35% and 50% openings model. Hence, the opening percentage should be carefully considered during the structural planning and design of multi-story buildings to maintain adequate lateral stiffness.
References
[1] Anagha M and Anoop P P, “Earthquake Response of Different Shapes of Tall Vertically Irregular Mivan Wall Building”, International Journal of Engineering Research & Technology (IJERT), ISSN: 2278-0181, Vol. 5 Issue 08, August-2016.
[2] Bansal P.P, Singh. S and Kuashik S.K,” Performance Evaluation of Monolithic and Conventional RCC Structures in Seismic Zones”, *Journal of Structural Engineering (ASCE)*, vol. 147, no. 4, 04021049, 2021.
[3] Bhanulatha G.N., Reddy M. Sreenivasulu and Dr. Reddy Y. Ramalinga, “Study of Dynamic Behaviour of MIVAN Structure with Different Percentage of Openings and Different Seismic Zones”, International Journal of Advances in Scientific Research and Engineering (IJASRE), Vol.3 (9) Oct - 2017.
[4] Choubey Anuj, Maru Savita “Optimum Shape for High Rise MIVAN and Conventional Structure in Seismic Loading” (IJRTE) Volume-8 Issue-5, January 2020.
[5] Ganar, A. S., & Patil, S. D. (2015), “Comparative analysis on cost and duration of MIVAN formwork building and Conventional Formwork building”, International Journal on Recent and Innovation Trends in Computing and Communication (IJRITCC), 3(12), 6472–6474.
[6] Hinduja Anmol, Sankle Tarun, Ahmed Mahroof, “Comparative Study of Mivan Technology and Conventional RCC Structures in High Seismic Zones”, International Journal for Research in Applied Science & Engineering Technology (IJRASET) Volume 13 Issue VI June 2025 ISSN: 2321-9653.
[7] Jamkar SS, “Structural behaviour of Mivan Structure for Dynamic Case”, International Journal Engineering Sciences & and Research Technology, 2013 ISSN:2277 [9-14].
[8] Kolekar Prasad, Nigade, V, Hajare Shivaji, “Analysis and Comparison of Mivan Formwork System with Conventional Formwork System” , International Research Journal of Engineering & Technology, Volume: 07 Issue: 06 | p-ISSN: 2395-0072, PP 4906-4910.
[9] Kote Aarti Nanasaheb, Nandeshwar Aahuti Ramesh, “Duration Comparison of Mivan Formwork over the Conventional Formwork”, International Journal Engineering Application for & Research in Management (IJREAM) ISSN: 2454-9150, 2020.
[10] Kulkarni P.B, “Seismic and deflection behavior of Mivan for Different Openings”, Pros ASCE. Structural Division Journal ST – 1 Vol 92 331- 403.
[11] Kushwaha Jatin, Kumar Nirmal Pradeep, Singh Lokesh “Analysis of a Tall Structure Considering Mivan Technology Under Lateral Load Using ETABS - A Review”, 2022 International Journal of Scientific Research in Civil Engineering | IJSRCE | Volume 6 | Issue 5 | ISSN: 2456-6667.
[12] Magarpatil HR, “Modeling the effect of Mivan walls on seismic performance”, Indian Concrete Journal, Volume 85, Page 15-43, 2012.
[13] Nisarga K, Madhukaran, “Structural Performance of Mivan Structural System Over Conventional Structural System”, International Journal of Scientific Research and Modern Technology (IJSRMT) Volume 1 Issue 1 2022.
[14] Patekar, N. B., & Shaikh, A. F. (2023),” Assessing the impact of conventional formwork and Mivan formwork on construction productivity and efficiency”, World Journal of Advanced Engineering Technology and Sciences, 9(1), 240–247. DOI: 10.30574/wjaets.2023.9.1.0168.
[15] Prajwal M L, Dr Murthy M Keshava, “Comparative Seismic Analysis of Multistorey Mivan Structures Over Conventionl RC Structures”, Journal of Emerging Technologies and Innovative Research (JETIR) July 2025, Volume 12, Issue 7 ISSN-2349-5162.
[16] Rana. R, Verma. A and Choudhary. R,” Cost-Benefits Analysis of Mivan and RCC Construction Methods,” *International Journal of Civil Engineering Research*, vol. 11, no. 2, pp. 98-110, 2020.
[17] Sajeet S. B, Gowda Supreeth S, “Earthquake Response of different shapes of Mivan wall Tall Buildings”, International Journal of Research in Engineering and Technology (IJRET), Volume: 04 Issue: 10 | Oct 2015.
[18] Singh. R, Kumar. A and Gupta. P, “Seismic Behaviour and Performance of Mivan Technology Buildings”, *Engineering Structures*, Volume 238, 112221, 2022.
[19] Walvekar Pawan M, Sonawadekar Hemant L, “Seismic Performance Evaluation of Mivan Structural System v/s Conventional Structural System with Effect of SSI by Pushover Analysis”, International Research Journal of Engineering and Technology (IRJET), Volume: 04 Issue: 06 | June -2017.
[20] Computers and Structures Inc., *ETABS version 22.5.0: Integrated Software for Structural Analysis and Design*, Berkely, California, USA,2022.