Self-poisoning using pesticides is the most common means of suicide in India. In such cases, the identification of pesticides is of utmost importance in managing the treatment and applying forensic protocols. In the present work fluorescent carbon dots using phenyl alanine as precursor was synthesized and characterized using FT-IR, NMR and TEM. The carbon dots showed enhanced fluorescence in the presence of organophosphate pesticide monocrotophos. Linearity studies showed a detection limit of 0.13 ?M. The carbon dot sensor showed good selectivity in the presence of other pesticides and good stability in the acidic pH.
Introduction
The study focuses on developing a simple, sensitive, and selective method for detecting monocrotophos, a highly hazardous organophosphate (OP) pesticide commonly used in India. Since OP pesticides are frequently involved in pesticide poisoning cases, their accurate identification is essential for appropriate medical treatment and forensic investigations.
Conventional detection techniques, such as GC-MS, LC-MS, electrochemical, and optical methods, often require sophisticated instruments, specialized reagents, and time-consuming procedures. To overcome these limitations, the researchers developed phenylalanine-based carbon dots (PhA-CDTs) as a fluorescence-based sensor for monocrotophos detection.
1. Synthesis and characterization
PhA-CDTs were synthesized using citric acid and L-phenylalanine through a thermal oxidation method at 220°C for 30 minutes.
The synthesized carbon dots were purified and obtained as a light-brown powder.
Their average particle size was found to be approximately 2–5 nm, with spherical or quasi-spherical morphology.
FT-IR, proton NMR, and TEM analyses confirmed the formation of carbon dots and the presence of phenylalanine on their surfaces.
2. Fluorescence-based detection
The synthesized PhA-CDTs exhibited weak fluorescence emission at 428 nm.
Upon interaction with different pesticides, monocrotophos produced a significant enhancement in fluorescence intensity.
This demonstrated the selective sensing ability of PhA-CDTs toward monocrotophos.
The detection procedure is simple: the carbon dots are dispersed in methanol, and their fluorescence response is observed under UV illumination.
3. Sensitivity and detection limit
The fluorescence response showed a linear relationship with monocrotophos concentration in the range of 0–20 µM.
The calculated limit of detection (LOD) was 0.13 µM.
Binding studies were also performed to evaluate the interaction between monocrotophos and the carbon dots.
Conclusion
In summary, phenyl alanine based carbon dots synthesized by a thermal oxidation method show weak fluorescence at 428 m; the emission intensity is enhanced when the CDTs interact with monocrotophos. The CDTs show excellent selectivity towards monocrotophos and are useful in the pH range of 3-7 for sensing purposes. The limit of detection for the reported method is 0.13 ?M which is significantly higher compared to some recently reported methods (Table 2). But when the sensor materials are compared, the CDTs in the present work are low cost and synthesized by a simple methodology. They can be lyophilized and stored for a long time. Moreover, the sensing method is also simple requiring no specialized equipments and can be easily performed on-site for forensic and environmental samples.
References
[1] O. Goswami, P. Mahanta, D. Kalita, R. Konwar, and D. S. Yadav, “A Three-Year Study on Acute Poisoning Cases Brought for Medico-Legal Autopsy in a North-Eastern City of India,” Open Access Emergency Medicine, vol. Volume 13, pp. 45–50, Feb. 2021, doi: 10.2147/oaem.s297083.
[2] G. D. Albano et al., “Toxicological Findings of Self-Poisoning Suicidal Deaths: A Systematic Review by Countries,” Toxics, vol. 10, no. 11, p. 654, Oct. 2022, doi: 10.3390/toxics10110654.
[3] T. Bonvoisin, L. Utyasheva, D. Knipe, D. Gunnell, and M. Eddleston, “Suicide by Pesticide Poisoning in India: A Review of Pesticide Regulations and Their Impact on Suicide Trends,” BMC Public Health, vol. 20, no. 1, Art. no. 251, Feb. 2020, doi: 10.1186/s12889-020-8339-z.
[4] World Health Organization, “WHO Recommended Classification of Pesticides by Hazard and Guidelines to Classification 2019,” 2019.
[5] M. A. Dar, B. Hamid, and G. Kaushik, “Temporal Trends in the Use and Concentration of Organophosphorus Pesticides in Indian Riverine Water, Toxicity, and Their Risk Assessment,” Regional Studies in Marine Science, vol. 59, Art. no. 102814, Apr. 2023, doi: 10.1016/j.rsma.2023.102814.
[6] R. Kaur and D. Goyal, “Toxicity and Degradation of the Insecticide Monocrotophos,” Environmental Chemistry Letters, vol. 17, no. 3, pp. 1299–1324, Apr. 2019, doi: 10.1007/s10311-019-00884-y.
[7] P. Raghu, T. Madhusudana Reddy, B. E. Kumara Swamy, B. N. Chandrashekar, K. Reddaiah, and M. Sreedhar, “Development of AChE Biosensor for the Determination of Methyl Parathion and Monocrotophos in Water and Fruit Samples: A Cyclic Voltammetric Study,” Journal of Electroanalytical Chemistry, vol. 665, pp. 76–82, Jan. 2012, doi: 10.1016/j.jelechem.2011.11.020.
[8] P. Raghu, M. R. Mohan Reddy, T. M. Reddy, Bahaddurghatta E. Kumara Swamy, and Kasetty Reddaiah, “Detection of Organophosphorous Pesticides Using a Monoenzyme Biosensor: A Voltammetric Study,” in Anal. Bioanal. Electrochem., CEE, Feb. 2012, pp. 1–16. Accessed: Nov. 12, 2026. [Online]. Available: www.abechem.com
[9] N. Chauhan and C. S. Pundir, “An Amperometric Acetylcholinesterase Sensor Based on Fe3O4 Nanoparticle/Multi-Walled Carbon Nanotube-Modified ITO-coated Glass Plate for the Detection of Pesticides,” Electrochimica Acta, vol. 67, pp. 79–86, Apr. 2012, doi: 10.1016/j.electacta.2012.02.012.
[10] Z. Bin, C. Yanhong, X. Jiaojiao, and Y. Jing, “Acetylcholinesterase Biosensor Based on Functionalized Surface of Carbon Nanotubes for Monocrotophos Detection,” Analytical Biochemistry, vol. 560, pp. 12–18, Nov. 2018, doi: 10.1016/j.ab.2018.08.024.
[11] Q. Long, H. Li, Y. Zhang, and S. Yao, “Upconversion Nanoparticle-Based Fluorescence Resonance Energy Transfer Assay for Organophosphorus Pesticides,” Biosensors and Bioelectronics, vol. 68, pp. 168–174, Jun. 2015, doi: 10.1016/j.bios.2014.12.046.
[12] N. S. Shrikrishna, A. Kaushik, and S. Gandhi, “Smartphone-Assisted Detection of Monocrotophos Pesticide Using a Portable Nano-Enabled Chromagrid-Lightbox System Towards Point-of-Care Application,” Chemosphere, vol. 330, p. 138704, Jul. 2023, doi: 10.1016/j.chemosphere.2023.138704.
[13] S. Dey, K. Modi, U. Panchal, M. Panchal, and V. K. Jain, “Detection of Small Molecular Toxins Using Azacalix[4]Arene Architecture and Its Theoretical Investigations,” Journal of Molecular Liquids, vol. 337, Art. no. 116337, Sep. 2021, doi: 10.1016/j.molliq.2021.116337.
[14] Q. Li et al., “Two Fe( Iii )/Eu( Iii ) Salophen Complex-Based Optical Sensors for Determination of Organophosphorus Pesticide Monocrotophos,” Analytical Methods, vol. 15, no. 19, pp. 2334–2342, 2023, doi: 10.1039/d3ay00255a.
[15] X. Sun, B. Liu, and K. Xia, “A Sensitive and Regenerable Biosensor for Organophosphate Pesticide Based on Self?Assembled Multilayer Film With CdTe as Fluorescence Probe,” Luminescence, vol. 26, no. 6, pp. 616–621, May 2011, doi: 10.1002/bio.1284.
[16] V. Gude, “Synthesis of Hydrophobic Photoluminescent Carbon Nanodots by Using L-Tyrosine and Citric Acid Through a Thermal Oxidation Route,” Beilstein Journal of Nanotechnology, vol. 5, pp. 1513–1522, Sep. 2014, doi: 10.3762/bjnano.5.164.
[17] P. Mandal and T. Ganguly, “Fluorescence Spectroscopic Characterization of the Interaction of Human Adult Hemoglobin and Two Isatins, 1-Methylisatin and 1-Phenylisatin: A Comparative Study,” The Journal of Physical Chemistry B, vol. 113, no. 45, pp. 14904–14913, Oct. 2009, doi: 10.1021/jp9062115.
[18] P. Mandal, D. Sahoo, P. Sarkar, K. Chakraborty, and S. Das, “Fluorescence Turn-on and Turn-off Sensing of Pesticides by Carbon Dot-Based Sensor,” New Journal of Chemistry, vol. 43, no. 30, pp. 12137–12151, Jul. 2019, doi: 10.1039/C9NJ03192H.
[19] L. Elsellami et al., “Kinetic of Adsorption and of Photocatalytic Degradation of Phenylalanine Effect of pH and Light Intensity,” Applied Catalysis A: General, vol. 380, no. 1, pp. 142–148, May 2010, doi: 10.1016/j.apcata.2010.03.054.
[20] X. Gong et al., “Rapid Detection of Organophosphorus Pesticide Monocrotophos by Pore Size-Regulated Amplified Fluorescence ‘Turn-on’ Response of Zr-MOF,” Analytica Chimica Acta, vol. 1352, Art. no. 343915, May 2025, doi: 10.1016/j.aca.2025.343915.
[21] N. S. Shrikrishna, G. P. Bhat, and S. Gandhi, “Aptamer Discovery via GO-SELEX and GrNP-SELEX for Monocrotophos and Its Comparative Analysis,” Microchimica Acta, vol. 193, no. 5, Art. no. 292, Apr. 2026, doi: 10.1007/s00604-026-08029-z.
[22] D. Devanand, T. Gakhar, S. Singh, and S. Nagpal, “Molecularly Imprinted Polymer-Based Non-Enzymatic Electrochemical Receptor for Detection of Organophosphate Pesticide: Monocrotophos,” International Journal of Environmental Research, vol. 20, no. 2, Feb. 2026, doi: 10.1007/s41742-025-01043-8.
[23] N. Gokila, V. Aurthi, S. Ramatchandirane Prabagaran, Y. Haldorai, and T. R. Kumar Ramasamy, “Electrochemical Impedimetric Enzyme-Less Detection of Non-Electroactive Organophosphate Pesticides Using Zirconium Metal Organic Framework,” Microchemical Journal, vol. 204, p. 111136, Sep. 2024, doi: 10.1016/j.microc.2024.111136.
[24] Y. Zhao, “Electrochemical Determination of Monocrotophos in Water and Fruits Using Acetylcholinesterase Immobilized on CNTs Modified Carbon Paste Electrode,” International Journal of Electrochemical Science, p. ArticleID:211221, Dec. 2021, doi: 10.20964/2021.12.30.
[25] N. S. Shrikrishna, P. Kolhe, and S. Gandhi, “Sensitive Detection of Monocrotophos Using a Voltametric Immunosensor With Randomly Layered Graphene Oxide (GO) on Fabricated Electrode,” Journal of Environmental Chemical Engineering, vol. 12, no. 2, Art. no. 112059, Apr. 2024, doi: 10.1016/j.jece.2024.112059.